| General |
|
1. Operating Temperature Range
|
-40 ~ +90
|
|
2. Storage Temperature Range
|
-40 ~ +105
|
|
3.Ballast life
|
>3000hrs (Room Temperature typically)
|
| Electric Output data |
|
4. Output wave
|
250~750Hz Square wave
|
|
5. Nominal output wattage
|
35+/-3W
|
|
6. Open circuit protection
|
Closing output within 4 seconds without any damage caused to ballast
|
|
7. Short circuit protection
|
Closing output within 4 seconds without any damage caused to ballast
|
|
8. Max. Current Output
|
2.6A at ignition moment and 0.5A after one Minute
|
|
9. In Rush output Wattage
|
Below 150W
|
|
10. Nominal voltage output
|
35~65V
|
|
11. Start voltage
|
15KV-23KV
|
| Electric input data |
|
12. Operating voltage range
|
12Vsystem
|
|
13. Max instantaneous current
|
ms, s , maintain nominal current after 60seconds
|
|
14. Max input wattage
|
52W (9V- 32V and 40 ~ +95)
|
|
15. Insufficient input voltage
|
Below 9V input might cause no functioning of Ballast circuit
|
|
16. Reverse protection
|
No defect allowed under 32V input
|